Environmental Limits
| Temperature Range: |
-55°C to +125°C |
| Thermal Shock: |
per Mil-Std-202, Method 107, Test Condition A |
| Vibration: |
per Mil-Std-202, Method 214, Test Condition B |
| Mechanical Shock : |
per Mil-Std-202, Method 213, Test Condition A, 40 Gs |
|
Phase Versus Flexure Reference Data
Astrolab performed phase tests on hundreds of microbend® cable assemblies. Following are two standard Astrolab tests with the corresponding data. In test one microbend® AR–5 assembly's were flexed 90° in a 0.1 inch radius directly behind the connector. In test two, microbend® AR–5 assembly's were flexed 180° with a 0.25 inch radius in the middle. Typical data is listed here:
|
TEST ONE |
TEST TWO |
26.5 GHz. |
1.5° |
4.5° |
18 GHz. |
1.0° |
3.1° |
12.4 GHz. |
0.6° |
2.3° |
2 GHz. |
0.1° |
0.4° |
|