Environmental Limits
| Temperature Range: |
-55°C to +125°C |
| Thermal Shock: |
per Mil-Std-202, Method 107, Test Condition A |
| Vibration: |
per Mil-Std-202, Method 214, Test Condition B |
| Shock: |
per Mil-Std-202, Method 213, Test Condition A, 40Gs |
|
Phase Versus Flexure Reference Data
Astrolab performed phase tests on hundreds of minibend cable assemblies. Following are two standard Astrolab tests with the corresponding data. In test one minibend® S-6 assembly's were flexed 90° in a 0.25 inch radius directly behind the connector. In test two, minibend® S-16 assemblies were flexed 180° with a 0.4 inch radius in the middle. Typical data is recorded here:
|
|
TEST ONE |
TEST TWO |
|
20 GHz. |
1.3° |
3.2° |
|
12.4 GHz. |
0.9° |
1.8° |
| 1 GHz. |
0.1° |
0.2° |
|