General
Characteristics
Materials:
BODIES, COUPLINGS, CABLE CLAMPING PARTS AND MOUNTING NUTS:
STEEL, CORROSION RESISTANT PER ASTM-A-582, UNS NO. S30300, CONDITION A, NON MAGNETIC
SILICON BRONZE CASTINGS PER ASTM-B-584 UNS NO. C87500
BRASS, FREE CUTTING, PER ASTM-B-16 UNS NO. C36000.
CENTER CONDUCTORS:
BERYLLIUM COPPER ALLOY PER ASTM-B-196, UNS NO. C17300, TEMPER TD04(H)
INSULATORS:
POLYTETRAFLUOROETHYLENE (PTFE) PER ASTM-D-1710
ASTM-D-4894, TYPE I, GRADE 1.
RETAINING RINGS:
BERYLLIUM COPPER, PER ASTM-B-197 OR B-441, UNS NO. C17200 TEMPER TD04(H)
CORROSION RESISTANT SPRING STEEL WIRE, COLD DRAWN, PER ASTM-A-313, UNS NO. S30200
PHOSPHOR BRONZE PER ASTM-B-159, SPRING TEMPER
LOCKWASHERS:
COPPER ALLOY CDA 425, UNS C42500 PER ASTM-B-591
COPPER ALLOY CDA 510, UNS C51000 PER ASTM-B-103
PHOSPHOR BRONZE, ALLOY, UNS C51000 PER ASTM-B-103
STEEL, CORROSION RESISTANT PER ASTM-A-176 UNS NO. S41000
O-RINGS AND GASKET:
SILICONE RUBBER PER GSA CID A-A-59588-2B AND SAE-AMS-3304
SOLDER:
SILVER AND SOFT PER J-STD-006
COPPER PER AMS 4701
Finishes:
STEEL BODIES, COUPLINGS, CABLE CLAMPING PARTS AND MOUNTING NUTS:
PASSIVATED PER SAE-AMS-QQ-P-35 OR
NICKEL PLATED .000100 IN MIN. THK. PER ASTM-B-733 TYPE 2 CLASS 3
SILICON BRONZE CASTINGS, AND BRASS BODIES COUPLINGS, CABLE CLAMPING PARTS:
NICKEL PLATED .000100 IN MIN. THK. PER ASTM-B-733 TYPE 2 CLASS 2 OR
SILVER PLATED .000200 IN MIN. THK. PER ASTM-B-700
CENTER CONDUCTORS
GOLD PLATED .000050 IN MIN. THK. PER ASTM-B-488, OVER
NICKEL PLATE, .000050 IN MIN. THK. PER SAE-AMS-QQ-N-290, CLASS 1
Design:
The design shall be such that the outline
dimensions shown in the catalog are met,
including the interface dimensions of MIL-STD-348
(where applicable)(Note: Designs are subject
to change without notice).
Contact
Resistance:
The center contact millivolt drop shall
be measured in accordance with para. 4.7.13.
Voltage
Standing Wave Ratio (VSWR):
Tested per Astrolab ANA Test Procedure.
Dielectric
Withstand Voltage (DWV):
Tested per MIL-STD-202, method 301 (60 Hz
at sea level).
Corona
Level:
Tested per para. 4.7.19.
RF
High Potential Withstand Voltage:
Tested per para. 4.7.20.
RF
Leakage:
Tested in accordance with para. 4.7.23
RF
Insertion Loss:
The insertion loss is tested in accordance
with Astrolab ANA procedure.
Mechanical
Testing
Connector
Durability:
Tested 500 + insertions and withdrawals
showing no evidence of mechanical failure.
Force
to Engage and Disengage:
2 Inch-lbs. Max. Torque for SMA, TNC, BNC;
6 Inch-lbs. Max. Torque for type N and SC.
Tested per para. 4.7.2.
Cable
Retention Force:
Tested per para. 4.7.21
Mating
Characteristics:
Tested in accordance with para. 4.7.4.
Hermetic
Seal:
Tested 100% in accordance with method I
I, MIL-STD-202, condition C procedure I,
at a leakage rate of 1 x 10-8 cc/sec. at
15 PSI of helium max.
Leakage:
Tested per para. 4.7.7 (Pressurized only).
Environmental
Testing (mil-std-202)
Corrosion:
Method 101, test condition B (5%
salt solution)
Vibration:
Method 204, test condition B.
Shock:
Method 213, test condition 1.
Thermal
Shock:
Method 107, test condition B.
Moisture
Resistance:
Method 106, step 7b omitted.
Engineering
Home | Back